Water & Environment

Saving Water in Gujranwala's Plastic Industry

Ikkarma Ahmad

5 min read 27 views Updated

Share this article

Gujranwala has many industries, including a large number of injection moulding facilities. They use water to cool down the mould inside the injection moulding machines, and then the fresh water is discharged into the drains. When I talked to 4 to 5 owners of injection moulding industries about this water discharge, I observed all of them don't even think about it. They think the cost of a recycling system is more than the cost of water. I think this could be a serious water conservation problem in Gujranwala.

Understanding Cooling Water Use

During the injection moulding process, hot melt plastic shapes into the mould, which heats the mould. It is then necessary to cool the mould; otherwise, the mould could damage the plastic pieces and slow down production. I personally measured water discharge with the help of a stopwatch at the rate of 3.5 litres per minute for the 100 grams of plastic product in the mould, while for the 1.5 kg plastic piece the mould needs 10 litres of water per minute for cooling. And all this water goes into the drains, i.e., 600 litres of water going into the waste stream in one hour of continuous operation of a single injection moulding machine. A company, DAYA, describes in its article that the cooling water requirements depend on the heater power; for instance, for 6kW of heater, water needs 10.5 litres per minute to cool the mould. Here we should know that the flow is not the same as consumption, but here in Gujranwala the fresh water flows through the mould and becomes consumption as the water discharges into the drains.

Recirculating Cooling System

The simple alternative is a recirculating system, which is also known as closed-loop system. In closed loop system, the water cools the mould and goes into the cooling tower. Then this cooled water again circulates into the mould and reduces the wastewater. This system needs simple set up such as a cooling tower or chiller based on the size of injection moulding machines, a pump, a storage tank, and piping arrangements. Most of the owners think this system is costly, but once this system is installed their production rate can increase as they will use cold water to cool down the mould and the maintenance for mould would also need less attention as it operates well with cold water. However, this system uses electricity and water can be lost through evaporation, blowdown, and other leakages, but it is far better than the waste of fresh water that is used once and discharged into drains.

What Can Gujranwala Learn from Service Station Recycling?

Punjab has already taken steps for car wash service stations to reduce wastewater by installing the recycling system. Punjab EPA issued orders for car wash stations to install wastewater recycling systems after the Lahore High Court ordered in February 2025. From September, 2024 to mid-January, 2025, the rainfall was about 42 percent below normal in Punjab, and a station was using approximately 400 litres of water per vehicle.

After the deadline passed, 3,525 service stations were covered during enforcement. The EPA had issued notices to 2,557 of them, sealed 159, and only 646 had installed recycling systems. If, for one vehicle, 400 litres of water is used, then comparing 3,525 stations covered by the EPA, with an average assumption of 10 vehicles per station, all these stations collectively generate approximately 14.1 million litres of wastewater per day.

Factories are not the same as car wash service stations. But the rules for wastewater can be followed in these injection moulding industries with a few changes, depending on the pre-assessment of these industries.

Recommendations for Industry and Environmental Departments

First of all, there must be an awareness campaign for water conservation for these injection moulding machines, and the owners should be made aware of how much it could damage the water sources that they are wasting. Then the industries should measure the waste of fresh water. Depending on the size of the industry and arrangements, each industry should consider whether it can install a cooling tower or chiller.

Environmental Protection and Climate Change Department (EP&CCD), with industrial associations, could start with a small pilot with some industries to set a baseline. They can then compare the water use before and after the change. It would provide actual data which can be used later for making rules and regulations.

Conclusion

In Gujranwala, the fresh water is used once in injection moulding machines and discharged into the drains. I observed many industries but talked to only 4 to 5 owners; therefore, a wider survey is needed for a complete assessment. After the enforcement drives for car wash service stations, only 646 of 3,525 stations installed the wastewater recycling system. This suggests that enforcement is difficult; that is why follow-up is necessary along with the rules and regulations. A next step could be taken to compare the cost of fresh water with the cost of a recycling system, so that owners can see the real data and understand the importance of water conservation.


About the author

Ikkarma Ahmad

Ikkarma Ahmad

Chemical Engineer

Ikkarma Ahmad is a Chemical Engineer and Climate Change Intern based in Gujranwala, Pakistan. His interests include industrial water conservation, waste management, environmental compliance, and sustainable manufacturing. Through environmental field activities, he has developed an interest in practical solutions that support resource efficiency and environmental protection.

Comments

No comments yet. Start the conversation.

Leave a comment

No account needed. Your Gmail address is never shown; only your name and comment appear.

Theme Water & Environment